WITH PROBE FOR MEASUREMENT
LOTUS MINI is all-round solution for all your need of CHLORINE DIOXIDE GENERATOR water disinfection. LOTUS MINI with probe measure system produces, doses and controls chlorine dioxide for water disinfection. It is equipped with ClO2 probe (SCL2 or SCL17) or an mV probe (ERH), a probe holder and a filter.
Chlorine dioxide is produced from diluted base chemicals: acid-chlorite process by hydrochloric acid (HCl 9%) and sodium chlorite (NaClO2 7,5%). Chlorine dioxide produced by LOTUS MINI is set to be proportional to the circulating water flow or based on a set-point – it is then dosed into the water flow. There is no storage of chlorine dioxide hence no chlorine dioxide gas or concentrated solutions exist outside of the process application.
LOTUS MINI chlorine-dioxide-gererator with probe measure is designed to produce chlorine dioxide in a reaction chamber. Multi-function valves on the injection points ensure the security of the reaction chamber.
The base chemicals are stored in tanks and fed into the reaction chamber through suction lances. Integrated level switches automatically stop the pumps when the tanks are empty.
GAS SENSOR OPTION
This model of LOTUS MINI is equipped with gas sensor detection.
FEATURES
- PERMANENT DATA STORAGE (WITHOUT BATTERY) with system log on display
- Stand-by input
- 3 flow sensors (mod. SEFL) input
- Real time production data
- Multifunction valve (MFKT/V)
- IP65 protection (NEMA4x) of LOTUS control instrument
- Working temperature: 0-45°C (32-110°F)
- PVC reaction chamber
- Instantaneous ClO2 production
- ClO2 dosing in PROPORTIONAL mode
- Pumps and SEFL flow sensors monitoring
- Service due data
- Water meter input
- Flow control input (flow alarm)
- Tank level controls (level alarms)
- LOTUS control instrument
- Pump for diluition water (grey)
- mA output
- ClO2 probe reading (LOTUS MINI SCL2 – LOTUS MINI SCL17)
- Temperature probe reading (probe and accessories not included)
- mV probe reading (LOTUS MINI ERH)
- ASA (Acrylonitrile Styrene Acrylate) enclosure
MODELS
LOTUS MINI 8 WITH PROBE MEASURE
- HOUR CAPACITY
- 8 g/h
- PRESSURE
- 8 bar
- CHEMICAL CONSUMPTION
- HCl 0.2 l/h
- NaClO2 0.2 l/h
- CONCENTRATION
- 2 g/l
LOTUS MINI 20 WITH PROBE MEASURE
- HOUR CAPACITY
- 20 g/h
- PRESSURE
- 8 bar
- CHEMICAL CONSUMPTION
- HCl 0.5 l/h
- NaClO2 0.5 l/h
- CONCENTRATION
- 2 g/l
COMMUNICATION
- ERMES
- MODBUS
CONFIGURATION
BASIC
- RS485 output to link other EMEC instruments
WIFI
- RS485 output to link other EMEC instruments
- Web ERMES remote control (PC, smartphone or tablet)
- Alarm messages via email
ADVANCED USB
- RS485 output to link other EMEC instruments
- Data Log on USB device
ETHERNET
- RS485 output to link other EMEC instruments
- Web ERMES remote control (PC, smartphone or tablet)
- Alarm messages via email
2G – 3G
- RS485 output to link other EMEC instruments
- Web ERMES remote control (PC, smartphone or tablet)
- Alarm messages via email
- Alarm messages via SMS
MODBUS
- Connection to other PLC instruments via RS485 or TCP/IP for reading and modifying parameters